GP

Gear Pump

Hydraulics
Run the live example Free · no sign-up · runs in your browser

The Gear Pump is a positive-displacement pump between port A (suction) and port B (outlet). Each shaft revolution moves one displacement of fluid from A to B, whatever the pressure; a little leaks back inside the pump as the pressure rises.

The shaft is an ordinary signal: wire a speed to ω, for instance a DC Motor's speed, and wire the pump's torque output back to that motor's load torque. The motor then slows as the pump works against pressure. Unwired, the pump runs at its speed parameter.

Real-World Analog: Represents an external gear pump driven by an electric motor or PTO shaft, providing positive-displacement hydraulic flow to industrial machinery or vehicle hydraulics.

Mathematical Model

Q = rac{V_d,omega}{2pi} - G,Delta p, qquad T = rac{V_d,Delta p}{2pi,eta_m}

Where:

  • Vd is the displacement (m³/rev), ω the shaft speed (rad/s)
  • Δp = p_B − p_A is the pressure rise (Pa)
  • G = (1 − η_v)·Vd·ω_nom / (2π·Δp_nom) is the leak conductance, fixed by the datasheet efficiency
  • η_m divides the ideal torque while pumping and multiplies it when the pump is driven backwards as a motor

Inputs & Outputs

Direction ID Label Type Status
→ In p A (in) number Required
→ In n B (out) number Required
→ In flange Shaft number Optional
→ In in ω number Optional
→ In H H number Optional
← Out torque T number Output
← Out flow Q number Output

Parameters

Parameters Label Type Default Description
displacement Displacement number 0.00001 Volume per revolution; 1e-5 m³ is 10 cm³/rev
volumetric_efficiency Volumetric efficiency number 0.95 Delivered over ideal flow at nominal speed and pressure; sets the internal leakage
mechanical_efficiency Mechanical efficiency number 0.9 Ideal over shaft torque while pumping
nominal_speed Nominal speed number 157.08 Speed at which the volumetric efficiency is rated; 157.08 rad/s is 1500 rpm
nominal_pressure Nominal pressure number 10000000 Pressure rise at which the volumetric efficiency is rated
speed Speed number 157.08 Shaft speed while the ω input is not wired
flow_ripple Gear-tooth flow ripple boolean false When enabled, models periodic flow pulsation at the tooth-meshing frequency (z · ω); disable for an ideal smooth pump
teeth_count Teeth per gear number 8 Number of teeth on each pump gear; sets both the visual gears and the flow-ripple frequency
gear_profile Gear profile select spur Spur involute gears produce sharper handover dips and higher ripple; helical gears mesh gradually with ~65% less ripple
ripple_amplitude Ripple amplitude override number 0 0 = automatic from teeth count and gear profile (~1/z²); set > 0 to override with a custom fractional amplitude

Usage Examples

DC motor driving the pump

The example examples/basic-gearpump.json: a 24 V DC motor turns a 2 cm³/rev pump into a 0.5 mm valve, with a 25 bar relief valve to tank. The outlet settles near 18 bar at about 29 rad/s. At t = 3 s the valve closes to 20 %: the pressure climbs into the relief valve, the pump torque rises and the motor slows. Run it on TR-BDF2.

Flow ripple and pressure pulsation analysis

Enabling flow_ripple: true with an 8-tooth spur profile generates high-frequency flow pulsations into a compliant hydraulic volume. A downstream pressure sensor captures the resulting acoustic pressure ripple and harmonic spectrum.

Remarks & Best Practices

  • Always give the flow a way out. A positive-displacement pump against a shut valve builds pressure without limit; put a Relief Valve from the outlet to tank.
  • Shaft coupling: the torque output feeds the motor's load-torque input. Speed and torque are exchanged as signals, not through a mechanical port.
  • Gauge pressure: every hydraulic pressure is relative to ambient; an open tank is 0 Pa.
  • Units: pressure in Pa (1 bar = 100 000 Pa), flow in m³/s (1 L/min ≈ 1.667e-5 m³/s), speed in rad/s (1 rpm = 0.1047 rad/s).

Related Components