Instant · No Sign-Up · 100% Free

Free Online Bode Plot Generator

Type a transfer function and see its magnitude and phase response, gain and phase margins, poles and zeros — instantly, in your browser.

Examples:
Move over the plot to read values.
Simulate it in BlockWerk →

The simulator opens a live Bode example with a step and sine input: set your coefficients in its Transfer Function block to see the time response next to the frequency response.

How Poles and Zeros Shape a Bode Plot

A Bode plot shows |G(jω)| in decibels and ∠G(jω) in degrees against frequency on a log axis. Every pole and zero bends the curves in a predictable way:

Element in G(s) Magnitude slope Phase change Where it acts
Real pole 1/(s/p + 1) −20 dB/decade 0° → −90° Corner at ω = p; −3 dB and −45° there.
Real zero (s/z + 1) +20 dB/decade 0° → +90° Corner at ω = z. A zero in the right half-plane adds −90° instead.
Integrator 1/s −20 dB/decade everywhere −90° constant Crosses 0 dB at ω = 1 rad/s.
Complex poles ωₙ²/(s² + 2ζωₙs + ωₙ²) −40 dB/decade 0° → −180° Resonance peak near ωₙ when ζ < 0.707.

Frequently Asked Questions

How do I enter my transfer function?
Type the coefficients of the numerator and the denominator in descending powers of s, separated by spaces or commas. G(s) = 10 / (s³ + 3s² + 2s) is numerator 10 and denominator 1 3 2 0. Missing powers are zeros. It is the same format the Transfer Function block in BlockWerk uses.
What are gain margin and phase margin?
Phase margin is how far the phase is above −180° where the magnitude crosses 0 dB; gain margin is how far the magnitude is below 0 dB where the phase crosses −180°. For the open-loop transfer function of a feedback loop, positive margins mean the closed loop is stable. A phase margin of 45–60° is a common design target.
Why does the phase not wrap at ±180°?
The phase is built from the angle of every pole and zero, so it runs continuously: a third-order system goes down to −270° instead of jumping back to +90°. That is the convention used in control textbooks and in MATLAB's bode.
Can I see the step response as well?
Yes. “Simulate it in BlockWerk” opens the free block diagram simulator with a live Bode example. Put your coefficients in its Transfer Function block, add a step input, and close the loop with a PID controller if you like — the PID tuner shows how.