Hydraulic Pipe
HydraulicsThe Hydraulic Pipe is a straight round pipe or hose between ports A and B. Its pressure drop follows the flow through it: proportional at low Reynolds numbers (laminar) and close to quadratic at high ones (turbulent).
Flow runs either way; a positive flow goes from A to B.
Real-World Analog: Represents a steel hydraulic line or high-pressure reinforced hose connecting pump, valves, and actuators with friction loss and pressure drop.
Mathematical Model
Where:
Re = ρ|v|D/μ,v = q/A,A = πD²/4fis the Haaland friction factor:1/√f = −1.8·log10((ε/D/3.7)^1.11 + 6.9/Re)- Between Re 2000 and 4000 the two are blended smoothly (value and slope continuous)
Inputs & Outputs
| Direction | ID | Label | Type | Status |
|---|---|---|---|---|
| → In | p |
A | number | Required |
| → In | n |
B | number | Required |
| → In | H |
H | number | Optional |
| ← Out | q_diss |
Q_diss | number | Output |
Parameters
| Parameters | Label | Type | Default | Description |
|---|---|---|---|---|
length |
Length | number | 1 |
Pipe length |
diameter |
Inner diameter | number | 0.01 |
Hydraulic (inner) diameter |
roughness |
Roughness | number | 0.0000015 |
Absolute wall roughness; 1.5 µm is drawn tube |
fluid_inertia |
Fluid inertia | boolean | true |
Mass of the fluid column (ρ·L/A): pressure surges such as water hammer |
segments |
Wave sections | number | 1 |
Pieces of a travelling-wave (Bergeron) line, so pressure waves arrive after L/a (needs Fluid inertia) |
wall_thickness |
Wall thickness | number | 0.002 |
With the wall modulus, sets the wave speed (Korteweg); used with wave sections |
wall_modulus |
Wall elastic modulus | number | 210000000000 |
Young's modulus of the wall: steel 2.1e11 Pa, PVC about 3e9 Pa |
Usage Examples
Valve closing against a relief valve
The example examples/basic-hydraulicpipe.json feeds a valve from a 20 bar oil supply through a pipe. The line settles near 15.8 bar; at t = 0.5 s the valve closes to 10 % and the 18 bar relief valve takes over the flow. Run it on TR-BDF2.
Water hammer when a valve shuts
The example examples/water-hammer.json runs water from 5 bar through a 100 m rigid pipe with fluid inertia, already flowing at t = 0 (steady_start on the supply). At t = 1 s the valve shuts at once and the pressure at the valve jumps from 4.7 to about 33 bar — Joukowsky's ρ·a·v₀ to within 0.5 % — and then swings around the supply pressure.
A pressure wave in a steel pipe
The example examples/water-hammer-wave.json runs water from 20 bar through 500 m of steel pipe (D = 0.1 m, wall 5 mm, a ≈ 1350 m/s) in 8 Bergeron pieces, already flowing at t = 0. When the valve shuts at t = 1 s the pressure at the valve jumps by about 13 bar, holds for exactly 2L/a ≈ 0.74 s while the wave travels to the supply and back, and then drops below the supply pressure.
Remarks & Best Practices
- Water hammer is on by default (
fluid_inertia,segments= 1) and the network starts in its steady state (steady_starton the FluidReservoir). - Gauge pressure: every hydraulic pressure is relative to ambient; an open tank is 0 Pa.
- Units: pressure in Pa (1 bar = 100 000 Pa), flow in m³/s (1 L/min ≈ 1.667e-5 m³/s).
- No cavitation: a pressure wave can drive the gauge pressure below −1 bar here; a real liquid would boil (column separation) instead.
Related Components
- FluidReservoir: Fluid Reservoir
- HydraulicValve: Hydraulic Valve
- ReliefValve: Relief Valve
- HydraulicVolume: Hydraulic Volume
- PressureSensor: Pressure Sensor
- FlowSensor: Flow Sensor