PRV

Relief Valve

Hydraulics
Run the live example Free · no sign-up · runs in your browser

The Relief Valve holds until the pressure drop across it reaches the cracking pressure, then passes flow so the pressure rises only slowly above it. Put it from a pump line to tank to cap the line pressure.

Its parameters are the ones on a datasheet: cracking pressure, and the pressure override at rated flow.

Real-World Analog: Represents a direct-acting safety pressure relief valve or counterbalance valve that cracks open to dump excess fluid back to tank when circuit pressure exceeds safety limits.

Mathematical Model

Δp={Ropen q+pcracktanh⁡(q/qleak)q≥0(Ropen+pcrack/qleak) qq<0\Delta p = \begin{cases} R_{open}\,q + p_{crack}\tanh(q/q_{leak}) & q \ge 0 \\ (R_{open} + p_{crack}/q_{leak})\,q & q < 0 \end{cases}

Where:

  • R_open = pressure_override / rated_flow
  • Below cracking pressure only about q_leak passes; reverse flow sees the shut valve
  • The slope is continuous at zero flow

Inputs & Outputs

Direction ID Label Type Status
→ In p In number Required
→ In n Tank number Required
→ In H H number Optional
← Out q_diss Q_diss number Output

Parameters

Parameters Label Type Default Description
cracking_pressure Cracking pressure number 10000000 Pressure drop at which the valve starts to open
pressure_override Pressure override number 1000000 Extra pressure drop above cracking at rated flow
rated_flow Rated flow number 0.001 Flow at cracking pressure plus override
leak_flow Leak flow number 1e-8 Flow that passes while the valve is shut
reseat_ratio Reseat Ratio (p_reseat / p_crack) number 1 Ratio of reseat/closing pressure to cracking pressure (1.0 = no hysteresis)

Usage Examples

Overpressure Protection and Cracking Bypass

The example examples/basic-reliefvalve.json protects a hydraulic line fed from a 25 bar supply, cracking open at 18 bar (1.8 MPa) to bypass excess flow to tank.

Valve closing against a relief valve

The example examples/basic-hydraulicpipe.json feeds a valve from a 20 bar oil supply through a pipe.

Remarks & Best Practices

  • Not a check valve: it blocks reverse flow, but has no cracking pressure in that direction.
  • Gauge pressure: every hydraulic pressure is relative to ambient; an open tank is 0 Pa.
  • Units: pressure in Pa (1 bar = 100 000 Pa), flow in m³/s (1 L/min ≈ 1.667e-5 m³/s).