Relief Valve
Hydraulics
Run the live example
Free · no sign-up · runs in your browser
The Relief Valve holds until the pressure drop across it reaches the cracking pressure, then passes flow so the pressure rises only slowly above it. Put it from a pump line to tank to cap the line pressure.
Its parameters are the ones on a datasheet: cracking pressure, and the pressure override at rated flow.
Real-World Analog: Represents a direct-acting safety pressure relief valve or counterbalance valve that cracks open to dump excess fluid back to tank when circuit pressure exceeds safety limits.
Mathematical Model
Where:
R_open = pressure_override / rated_flow- Below cracking pressure only about
q_leakpasses; reverse flow sees the shut valve - The slope is continuous at zero flow
Inputs & Outputs
| Direction | ID | Label | Type | Status |
|---|---|---|---|---|
| → In | p |
In | number | Required |
| → In | n |
Tank | number | Required |
| → In | H |
H | number | Optional |
| ← Out | q_diss |
Q_diss | number | Output |
Parameters
| Parameters | Label | Type | Default | Description |
|---|---|---|---|---|
cracking_pressure |
Cracking pressure | number | 10000000 |
Pressure drop at which the valve starts to open |
pressure_override |
Pressure override | number | 1000000 |
Extra pressure drop above cracking at rated flow |
rated_flow |
Rated flow | number | 0.001 |
Flow at cracking pressure plus override |
leak_flow |
Leak flow | number | 1e-8 |
Flow that passes while the valve is shut |
reseat_ratio |
Reseat Ratio (p_reseat / p_crack) | number | 1 |
Ratio of reseat/closing pressure to cracking pressure (1.0 = no hysteresis) |
Usage Examples
Overpressure Protection and Cracking Bypass
The example examples/basic-reliefvalve.json protects a hydraulic line fed from a 25 bar supply, cracking open at 18 bar (1.8 MPa) to bypass excess flow to tank.
Valve closing against a relief valve
The example examples/basic-hydraulicpipe.json feeds a valve from a 20 bar oil supply through a pipe.
Remarks & Best Practices
- Not a check valve: it blocks reverse flow, but has no cracking pressure in that direction.
- Gauge pressure: every hydraulic pressure is relative to ambient; an open tank is 0 Pa.
- Units: pressure in Pa (1 bar = 100 000 Pa), flow in m³/s (1 L/min ≈ 1.667e-5 m³/s).
Related Components
- FluidReservoir: Fluid Reservoir
- HydraulicPipe: Hydraulic Pipe
- HydraulicValve: Hydraulic Valve
- HydraulicVolume: Hydraulic Volume
- PressureSensor: Pressure Sensor
- FlowSensor: Flow Sensor