Pneumatic Pipe
Pneumatics
Run the live example
Free · no sign-up · runs in your browser
The Pneumatic Pipe models an airline, hose, or distribution manifold causing pressure drop and flow resistance according to geometry and fluid friction.
Real-World Analog: Represents a pneumatic hose, polyurethane airline tubing, or distribution manifold with laminar/turbulent flow resistance and pressure drop.
Mathematical Model
Inputs & Outputs
| Direction | ID | Label | Type | Status |
|---|---|---|---|---|
| → In | port_a |
A | number | Required |
| → In | port_b |
B | number | Required |
Parameters
| Parameters | Label | Type | Default | Description |
|---|---|---|---|---|
length |
Length | number | 1 |
Pipe length in meters |
diameter |
Inner diameter | number | 0.01 |
Inner bore diameter of the airline |
sonic_conductance |
Sonic conductance | number | - |
Equivalent line sonic conductance C; leave empty to estimate it from length and diameter |
critical_pressure_ratio |
Critical ratio (b) | number | 0.528 |
Critical pressure ratio b (0.528 for air) |
Usage Examples
Long distribution line pressure drop
In examples/basic-pneumaticpipe.json, a 5-meter pneumatic pipe (8 mm bore) delivers compressed air from a 6 bar supply to an exhaust valve, measuring the friction pressure drop.
Sizing airline diameter
Comparing pressure drop when switching between 6 mm and 10 mm internal bore hoses.
Remarks & Best Practices
- Friction losses: Accounts for wall friction and line geometry.
- Conserving: Conserves mass flow rate between port A and port B.