QSENS

Heat Flow Sensor

Thermal
Run the live example Free · no sign-up · runs in your browser

The Heat Flow Sensor block measures the rate of thermal energy transfer (heat flow QQ) passing through its branch from port A to port B without introducing any thermal resistance (ΔT=0 K\Delta T = 0\text{ K}). It converts the physical through-variable into a standard numerical causal signal in Watts (W).

Because it acts as an ideal zero-impedance thermal branch, it does not alter the temperature distribution or dynamics of the connected network.

Real-World Analog: Represents a thin-film heat flux transducer measuring through heat energy flow rate in Watts with zero thermal resistance.

Mathematical Model

The measured heat flow through the sensor is:

y=QA→By = Q_{A \to B}

Where:

  • y is the causal output signal in Watts (W).
  • Q_{A \to B} is the net heat flow rate passing from port A to port B in Watts (W).
  • Temperature drop across the ideal sensor is identically zero: TA−TB=0 KT_A - T_B = 0\text{ K}.

Inputs & Outputs

Direction ID Label Type Status
→ In p A number Required
→ In n B number Required
← Out out Q number Output

Usage Examples

In-Line Calorimetric Flow Measurement

Measure heat flux conducting from a thermal body into ambient:

ThermalMass -> HeatFlowSensor -> ThermalResistor -> Ambient

Heat Loss Through Insulation Slab

Quantify instantaneous heat leakage passing through an insulated barrier:

TemperatureSource(hot) -> HeatFlowSensor -> ThermalResistor(insulation) -> Ambient

Remarks & Best Practices

  • Zero Resistance: Introduces an ideal internal constraint (TA−TB=0T_A - T_B = 0) into the MNA equations, measuring heat flow transparently.
  • Directional Sign Convention: Positive output indicates heat flowing from port A to port B; negative indicates reverse flow.
  • Calorimetric Accuracy: Solves the exact conservative branch flux without numerical differentiation.
  • WASM Performance: Stamped and solved directly in compiled WebAssembly.

Related Components