CONV

Convective Heat Transfer

Thermal
Run the live example Free · no sign-up · runs in your browser

The Convection block models Newton's law of cooling between a solid boundary surface and a moving fluid stream (liquid or gas). It acts as an equivalent thermal resistance between thermal port A (surface) and thermal port B (fluid stream).

Because Convection is an acausal conserving component, heat can transfer from surface to fluid (cooling) or from fluid to surface (heating), stamped into the conductance matrix during Modified Nodal Analysis (MNA).

Real-World Analog: Represents natural or forced air cooling across a finned heat sink or radiator surface transferring heat into ambient air.

Mathematical Model

The convective heat transfer rate is defined by Newton's law of cooling:

Q=h⋅A⋅(TA−TB)Q = h \cdot A \cdot (T_A - T_B)

Where:

  • Q is the convective heat flow rate from port A to port B in Watts (W).
  • h is the convective heat transfer coefficient in Watts per square meter-Kelvin (W/(m2⋅K)\text{W}/(\text{m}^2\cdot\text{K})).
  • A is the heat transfer surface area in square meters (m2\text{m}^2).
  • T_A is the solid surface temperature at port A in Kelvin (K).
  • T_B is the fluid bulk temperature at port B in Kelvin (K).

In conductance terms, the equivalent thermal resistance is:

Rth,conv=1h⋅AR_{th,conv} = \frac{1}{h \cdot A}

Inputs & Outputs

Direction ID Label Type Status
→ In p A number Required
→ In n B number Required

Parameters

Parameters Label Type Default Description
heat_transfer_coefficient Heat Transfer Coeff. (h) number 25 Convective heat transfer coefficient in W/(m²·K) (e.g. 5-25 for air natural convection, 50-500 for forced air, 500-10000 for water)
surface_area Surface Area (A) number 0.1 Effective convective heat exchange surface area in square meters
emissivity Surface Emissivity (ε) number 0 Surface emissivity for linearized Stefan-Boltzmann radiation (0 = pure convection, 0.8-0.95 for painted/anodized surfaces)
reference_temperature Radiation Ref. Temp. (T_ref) number 293.15 Reference temperature in Kelvin used for radiative linearization: h_rad = 4·ε·σ·T_ref³

Usage Examples

Air-Cooled Heat Sink Fin

Cool an electronic component using natural air convection:

ThermalMass(CPU) -> Convection(h: 15, area: 0.05) -> TemperatureSource(ambient: 298.15)

Liquid Cooling Channel

Model forced convective heat dissipation inside a liquid-cooled cold plate:

ThermalMass(motor) -> Convection(h: 1500, area: 0.02) -> TemperatureSource(coolant: 310)

Remarks & Best Practices

  • Regime Flexibility: Accommodates both free/natural convection and forced convection by setting appropriate hh values.
  • Equivalent Conductance: Stamped as conductance G=h⋅AG = h \cdot A in the MNA system matrix.
  • Second Law Consistency: Heat exchange naturally ceases when surface temperature reaches fluid temperature (TA=TBT_A = T_B).
  • WASM Performance: Evaluated at machine speed in WebAssembly without numerical stiffness artifacts.

Related Components