MSENS

Pneumatic Mass Flow Sensor

Pneumatics
Run the live example Free · no sign-up · runs in your browser

The Pneumatic Mass Flow Sensor measures through mass flow rate entering terminal A and exiting terminal B with zero pressure drop.

Real-World Analog: Corresponds to an inline thermal mass flow meter (such as a Coriolis meter or hot-wire anemometer) installed in a factory compressed air line to monitor instantaneous air consumption.

Mathematical Model

The sensor implements an ideal conserving flow transducer that leaves node pressures unchanged while reporting the mass throughput:

out=m˙A→Bout = \dot{m}_{A \to B}

By mass conservation across the conserving pneumatic domain:

m˙A+m˙B=0,pA=pB\dot{m}_A + \dot{m}_B = 0, \quad p_A = p_B

Inputs & Outputs

Direction ID Label Type Status
→ In port_a A number Required
→ In port_b B number Required
← Out out out number Output

Usage Examples

Air consumption metering

In examples/basic-pneumaticmassflowsensor.json, the sensor measures inline mass flow in kg/s passing from a 6 bar supply through a calibrated pneumatic orifice into atmospheric discharge, scaled to g/s for clear scope readout.

Leak detection and air audit

Comparing mass flow at the compressor manifold against the sum of branch consumers to identify airline leaks, fitting ruptures, or unmetered pneumatic demand.

Remarks & Best Practices

  • Zero impedance: Ideal through meter with zero series resistance or pressure drop (pA=pBp_A = p_B).
  • Sign convention: Positive mass flow indicates fluid entering terminal A and exiting terminal B.
  • Unit conversion: Outputs mass flow in kg/s\text{kg/s}. Multiply by 10001000 using a Gain block for g/s\text{g/s}, or by 36003600 for kg/h\text{kg/h}.