ATM

Pneumatic Atmosphere

Pneumatics
Run the live example Free · no sign-up · runs in your browser

The Pneumatic Atmosphere block establishes the reference potential for the pneumatic network, fixing ambient atmospheric pressure at 101325 Pa (1.01325 bar abs). Every pneumatic island requires an atmospheric reference or pressure source.

Real-World Analog: Represents the ambient room or open atmosphere (101,325 Pa at 20°C), serving as the exhaust dump or suction intake for pneumatic circuits.

Mathematical Model

pport=patm=101325 Pap_{port} = p_{atm} = 101325 \text{ Pa}

Inputs & Outputs

Direction ID Label Type Status
→ In port Port number Required

Parameters

Parameters Label Type Default Description
pressure Atmospheric pressure number 101325 Standard atmospheric pressure (default: 101325 Pa = 1.01325 bar)
temperature Ambient temperature number 293.15 Ambient temperature (293.15 K = 20 °C)

Usage Examples

Ambient venting and receiver exhaust

In examples/basic-pneumaticatmosphere.json, the Pneumatic Atmosphere block anchors both the compressor suction return and chamber differential exhaust ports to standard ambient pressure (101325 Pa abs).

Open intake compressor

A compressor draws intake air from the ambient atmosphere.

Remarks & Best Practices

  • Reference node: Serves as the pneumatic equivalent of Electrical Ground or Fluid Reservoir.
  • Mandatory reference: Every pneumatic circuit needs at least one reference block.